Pulmonary Abnormality Screening on Chest X-Rays from Different Machine Specifications: A Generalized AI-Based Image Manipulation Pipeline

Published

European Radiology Experimental, 2023, 7.1: 68

Authors

Heejun Shin1, Taehee Kim1, Juhyung Park2, Hruthvik Raj1, Muhammad Shahid Jabbar1,
Zeleke Desalegn Abebaw1, Jongho Lee2, Cong Cung Van3, Hyungjin Kim4, and Dongmyung Shin1

Affiliations

1Artifcial Intelligence Engineering Division, RadiSen Co., Ltd, Seoul, Korea.
2Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, Korea.
3Department of Radiology, National Lung Hospital, Hanoi, Vietnam.
4Department of Radiology, Seoul National University Hospital, Seoul, Korea.

Background

Chest x-ray is commonly used for pulmonary abnormality screening. However, since the image characteristics of x-rays highly depend on the machine specifcations, an artifcial intelligence (AI) model developed for specifc equipment usually fails when clinically applied to various machines. To overcome this problem, we propose an image manipulation pipeline.

Methods

A total of 15,010 chest x-rays from systems with diferent generators/detectors were retrospectively collected from fve institutions from May 2020 to February 2021. We developed an AI model to classify pulmonary abnormalities using x-rays from a single system. Then, we externally tested its performance on chest x-rays from various machine specifcations. We compared the area under the receiver operating characteristics curve (AUC) of AI models
developed using conventional image processing pipelines (histogram equalization [HE], contrast-limited histogram equalization [CLAHE], and unsharp masking [UM] with common data augmentations) with that of the proposed manipulation pipeline (XM-pipeline).

Results


The XM-pipeline model showed the highest performance for all the datasets of diferent machine specifcations, such as chest x-rays acquired from a computed radiography system (n=356, AUC 0.944 for XM-pipeline versus 0.917 for HE, 0.705 for CLAHE, 0.544 for UM, p≤ 0.001, for all) and from a mobile x-ray generator (n=204, AUC 0.949
for XM-pipeline versus 0.933 for HE, p=0.042, 0.932 for CLAHE (p=0.009), 0.925 for UM (p=0.001).

Conclusions


Applying the XM-pipeline to AI training increased the diagnostic performance of the AI model
on the chest x-rays of diferent machine confgurations.

Share:

1. Purpose of collecting and using personal information

Sub-One Co. Ltd. collects personal information according to items of personal information collected to receive customer counseling and process inquiries.


2. Items of personal information collected
– Required: Email
– Selections: Company name, mobile phone number


3. Retention and period of use of personal information
Sub-One Co. Ltd. shall be destroyed after storing the information for 3 years after the purpose of personal information collection and use has been achieved.

 

Provided, That if it is necessary to preserve it under the provisions of the relevant statutes, member information shall be kept for a certain period of time prescribed by the relevant statutes.